D-Smart set-top box All models error codes
Codes
- F02Error codeFault detected during safety edge testMedium
- F03Error codeThe safety edge detected an obstacle during the closing manoeuvreMedium
- F06Error codeThe motor direction of rotation is incorrectMedium
- F07Error codeError in photocell test on NDA030 boardMedium
- F09Error codeCommunication problem on I2C busMedium
- F10Error codeCommunication error with electronic encoder (encoder disconnected or broken)Medium
- F13Error codeError in release cord test (cord loose)Medium
- F14Error codeEEPROM checksum error (serious error)Medium
- F15Error codeInput photocell activation on NDA030 board. The error appears if the photocell is activated before the door has reached the upper limit stopMedium
- F16Error codeThe door reached the limit stop faster than the time set in P63Medium
- F17Error codeThe loop on channel 1 of the loop detector is disconnectedMedium
- F18Error codeThe loop on channel 2 of the loop detector is disconnectedMedium
- F19Error codeThe “Fire detector” input on the NDA030 board is activatedMedium
- F20Error codeAfter the number of attempts made, set in P44, automatic closing was interrupted Automatic closing will be automatically disabledMedium
- F22Error codeEncoder error (only valid for Kostal encoders)Medium
- F23Error codeCommunication with Nice inverter interruptedMedium
- F24Error codeFault detected on motor drive relay contactMedium
- F25Error codeFault detected on contact of the motor direction relaysMedium
- F26Error codeCommunication error with Nice inverter (generic error)Medium
- F27Error codeCommunication error with Nice inverter (command rejected by inverter)Medium
- F28Error codeCommunication error with Nice inverter (timeout after n seconds of no inverter response)Medium
- F29Error codeDoor bolt fails to lock/unlock within the time set in P87Medium
- F30Error codeCommunication error with Nice inverter (wrong inverter address)Medium
- F32Error codeCommunication error with Nice inverter (inverter did not activate correctly)Medium
- F33Error codeFault detected on brake control relay contact (only for D-Pro Automatic R10)Critical
- F34Error codeError in photocell test (only for D-Pro Automatic R10)Medium
- F60Error codeCommunication error with inverter (inverter error not read correctly)Medium
- F61Error codeCommunication error with inverter (inverter error reading not possible)Medium
- F100Error codeRelease cable input activation (Terminal X2-J10)Medium
- F104Error codeMotor thermal relay activation or manual release activationMedium
- F200Error codeShort-circuit protection. The error will first appear as “E200” and then change to “F200” when it can be clearedMedium
- F203Error codeOver- or under-temperature protectionMedium
- F204Error codeIGBT module overload protection (motor control) The error will first appear as “E204” and then change to “F204” when it can be clearedMedium
- F205Error codeMotor overload protection (current too high on phases: see parameter U24) The error will first appear as “E205” and then change to “F205” when it can be clearedMedium
- F206Error codeError history (if U5 value > 29)Low
- F208Error codeProtection from broken cables (missing motor phase)Medium
- F209Error codeProtection for communication failure with D-Pro AutomaticMedium
- F210Error codeProtection for communication failure with encoderMedium