- c4Error code2.3 INTENDED USE FAAC series 746 C - 844 C gearmotors have been designed to control motorized horizontal movement sliding gates intended for installation in areas that are accessible to people, the main purpose of which is to provide safe access for goods, vehicles and people to industrial, commercial or residential buildings. Only one gearmotor must be installed for each leaf. The system requires a special foundation plate (supplied separately) to be embedded in a plinth. The gate must be moved via a drive pinion and a rack (supplied separately). To move the gate manually, follow the instructions in section § Manual operation. Any other use that is not expressly specified in these instructions is prohibited and could affect the integrity of the product and/or represent a source of dangerHazard level: Medium
- DL1Error codePower ON and BUS -2EASY communicating with boardHazard level: Medium
- DL5Error codeerrors/alaHazard level: Medium
- DL19Error codePRESSURE SIGNALLING LED “RESET SW” Push-buttonHazard level: Low
- DL20Error codeALARM SIGNALLING LED “ALARM”Hazard level: Medium
- DL22Error codeL23 DISPLAY J17 J10 8.8. DL10 24 EDOP + - ER DL6 23 EDOP DL5 DL7 22 EDCL + DL4 DL20 21 EDCL - DL3 20 IN7 CL H -_ ++ -- FF 19 18 IN6 OP H 11 DL21 12 OU_ T 2 F2 J9 11 OUT 1 10 +24 V J6 J12 J14 9 +24 V 8 - DL25 7 - DL24 6 - DL13 5 IN5 STOP DL14 4 IN4 FSW CL DL15 3 IN3 FSW OP ENC pcb DL16 2 IN2 OP-B DL17 1 IN1 OP-A F1 J8 2EASY DL1 DL2 LED (see section § Diagnostics) DL1 Bus 2Easy operation DL2 Bus 2Easy line diagnostics DL3 RADIO XF FDS or XF channel 1 (CH1) DL4 RADIO XF FDS or XF channel 2 (CH2) DL5 Errors/alarms DL6 Encoder DL7 Closing sensitive edges DL10 Opening sensitive edges DL11 Accessories power supply +24 V" DL12 Power supply +5 V" DL13 Stop command (STOP) DL14 Closing photocells DL15 Opening photocells DL16 OPEN B DL17 OPEN A ) DL20 Forced closing command DL21 Forced opening command DL22 Radio activity RP channel 1 (CH1) DL23 Radio activity RP channel 2 (CH2) DL24 Opening/closing limit switch (depending on the direc- DL25 tion of travel) 19Hazard level: Medium
- Er01Error codeBoard failureHazard level: Medium
- Er02Error codeBoard thermal protectionHazard level: Medium
- Er06Error codeEncoder 2 faultHazard level: Medium
- Er07Error codeMotor 1 faultHazard level: Medium
- Er08Error codeMotor 2 faultHazard level: Medium
- Er16Error codeEncoder 1 faultHazard level: Medium
- Er25Error codeElectric lock (LOCK1) faultHazard level: Medium
- Er30Error codeFlashing light short circuit or overloadHazard level: Medium
- Er35Error codeBUS-2easy device fault or address conflictHazard level: Medium
- Er36Error codeBUS-2easy short circuit or overloadHazard level: Medium
- Er48Error codeLimit-switch fault, leaf 1Hazard level: Medium
- Er49Error codeLimit-switch fault, leaf 2Hazard level: Medium