Kumtel Tüm modeller arıza kodları
Kodlar
- FLT01Arıza koduA nonrecoverable microprocessor error has occurredTehlike düzeyi: Orta
- FLT02Arıza koduAn Invalid Configuration fault occurs if a configuration parameter is set to an illegal value or combination of values. See the Configuration Fault Codes on page 141Tehlike düzeyi: Orta
- FLT03Arıza koduAn MP Output fault occurs if an internal error is detected in the circuit that removes motion producing power from the drive terminalsTehlike düzeyi: Orta
- FLT04Arıza koduA Reset Powerup fault occurs if the reset type is configured for Manual or Manual Monitored and the Reset In input is detected _ as ON when power is cycledTehlike düzeyi: Orta
- FLT05Arıza koduA Feedback 1 fault occurs if any of these conditions are detected at encoder 1: • An open wire is detected. • A short-circuit is detected. • A sine/cosine fault exists, that is the amplitude of the sine signal squared plus the amplitude of the cosine signal squared is not equal to a constant value. • The feedback signals indicate a frequency greater than or equal to 100 kHz for a Sine/cosine encoder or 200 kHz for a incremental encoder. • Illegal encoder signal transitions are detected. • Incorrect Overspeed Response Time setting (refer to Table 15 on page 47)Tehlike düzeyi: Orta
- FLT06Arıza koduA Feedback 2 fault occurs if any of these conditions are detected at encoder 2: • Illegal encoder signal transitions are detected. • The feedback signals indicate a frequency greater than or equal to 200 kHzTehlike düzeyi: Orta
- FLT07Arıza koduA Dual Feedback Speed fault occurs if an error is detected between the speed from the first encoder and the speed from the second encoder. Valid speed-comparison values are determined by the configured Feedback Speed Ratio and Feedback Speed ToleranceTehlike düzeyi: Orta
- FLT08Arıza koduA Dual Feedback Position fault occurs if a discrepancy is detected between the relative position change of encoder 1 and the relative position change of encoder 2 since the last SS ResetTehlike düzeyi: Orta
- FLT10Arıza koduSS OUT nn (1)Tehlike düzeyi: Orta
- FLT11Arıza koduA Deceleration fault occurs if the speed is detected at greater than the limit specified for the configured Stop Delay [Maximum Stop Time] when the configured Stop Category is Safe Stop 1 or 2Tehlike düzeyi: Orta
- FLT12Arıza koduA Stop Speed fault occurs when the drive is configured for a Stop Category that includes Standstill Speed checking (Safe Stop 1 or 2, and Safe Torque Off with Standstill Speed Checking) and the detected speed is greater than the configured Standstill Speed at the end of the configured Stop Delay [Maximum Stop Time]Tehlike düzeyi: Orta
- FLT13Arıza koduIf the drive is configured for a stop type that includes stopped speed checking, a Motion After Stop fault occurs if either of the following is detected after the system is stopped and the door has been unlocked: • Speed greater than the configured Standstill Speed • A position change greater than the configured Standstill Position limitTehlike düzeyi: Orta
- FLT14Arıza koduSLS INTehlike düzeyi: Orta
- FLT15Arıza koduSLS OUTTehlike düzeyi: Orta
- FLT16Arıza koduMotion FaultsTehlike düzeyi: Orta
- FLT21Arıza koduMonitor FaultTehlike düzeyi: Orta
- FLT22Arıza koduDC OUTTehlike düzeyi: Orta
- FLT24Arıza koduLOCK MONITORINGTehlike düzeyi: Orta
- FLT25Arıza koduESM INTehlike düzeyi: Orta
- FLT27Arıza koduAn Encoder 1 Voltage fault occurs if the encoder voltage at encoder 1 is detected as out of rangeTehlike düzeyi: Yüksek
- FLT28Arıza koduAn Encoder 2 Voltage fault occurs if the encoder voltage at encoder 2 is detected as out of rangeTehlike düzeyi: Yüksek