Chappee All models error codes
Codes
- A1Error codeFault with the room temperature sensor on the indoor unitHazard level: Medium
- A2Error codeFault with the temperature sensor in the middle of the indoor unit's evaporatorHazard level: Medium
- A3Error codeFault with the temperature sensor at evaporator inletHazard level: Medium
- A4Error codeFault with the temperature sensor at evaporator outletHazard level: Medium
- A5Error codeIndoor unit condensate pump anomaly (fault with the drainage)Hazard level: Medium
- A6Error codeFan motor fault in the indoor unitHazard level: Medium
- A8Error codeFault in the EEPROM module of the indoor unitHazard level: Medium
- A9Error codeAbnormal communication between the indoor unit and the outdoor unitHazard level: Medium
- AAError codeAbnormal communication between the indoor unit and the wired controllerHazard level: Medium
- ADError codeIndoor frost protectionHazard level: Medium
- BKError codeBK BK BK BK BK BRHazard level: Medium
- BLError codeWH BK BR BK BK BKHazard level: Medium
- BRError codeBK BK BK BK GN/Hazard level: Medium
- C1Error codeFault with the environmental temperature sensor on the outdoor unitHazard level: Medium
- C2Error codeFault with the defrosting temperature sensor on the outdoor unitHazard level: Medium
- C3Error codeFault with the discharge temperature sensor on the outdoor unitHazard level: Medium
- C6Error codeFault with the suction temperature sensor on the outdoor unitHazard level: Medium
- C8Error codeFault with the temperature sensor in the middle of the outdoor condenserHazard level: Medium
- E1Error codeFour-way valve faultHazard level: Medium
- E2Error codeFault with the refrigerant temperature sensor on the outdoor unitHazard level: High
- E3Error codeExcessive discharge temperature protectionHazard level: Medium
- E5Error codeCommunication error between the indoor Connection wire, main internal control panel, main exHazard level: Medium
- E8Error codeCooling: protection of the outdoor unit against high temperaturesHazard level: Medium
- F1Error codeFault with the inverter module protection (IPM)Hazard level: Medium
- F2Error codeFault with the outdoor unit PCB protection (PFC) condenserHazard level: Medium
- F3Error codeFault with the compressor synchronismHazard level: High
- F4Error codeFault with the discharge temperature sensorHazard level: Medium
- F6Error codeFault with the outdoor temperature sensorHazard level: Medium
- F9Error codeFault with the outdoor unit EPROMHazard level: Medium
- FAError codeIntake temperature sensor errorHazard level: Medium
- FHError codeLow discharge temperature protectionHazard level: Medium
- FRError codeDo not allow the refrigerant to escape into the atmosphere or theHazard level: High
- GYError codeGN/ GN/ BL RD GN/ BL BL BK BK BK BK BK BK BK BKHazard level: Medium
- H1Error codeHigh pressure switch protectionHazard level: High
- H4Error codeLow pressure switch protectionHazard level: Medium
- J2Error codeAbnormal communication between the outdoor unit and the indoor unitHazard level: Medium
- J3Error codeAbnormal communication between the driver PCB and main PCB of outdoor unitHazard level: Medium
- J7Error codeFault with the outdoor unit EPROMHazard level: Medium
- P4Error codeCondenser overload protection (in cooling mode)Hazard level: Medium
- P5Error codeDischarge temperature protectionHazard level: Medium
- P6Error codeEvaporator overload protection (in heating mode)Hazard level: Medium
- P7Error codeIndoor unit freeze protection (in cooling mode)Hazard level: Medium
- P8Error codeOutdoor unit overcurrent protectionHazard level: Medium
- X01Error codeX62 PE-2 PE-1 X41 X51 PE-4Hazard level: Medium
- X2Error codeStatus LIN-Bus PWM 0-10Hazard level: Medium
- X5Error codeX6 X7 X8 X10 X11Hazard level: Medium
- X22Error codeXC01 X25 X21Hazard level: Medium
- X32Error codeX115 X102 X103 X104 X1151Hazard level: Medium
- X51Error codeX105 X101 X115 X1151 X111Hazard level: Medium
- X81Error codeX102 X104 X114 X112Hazard level: Medium