Ghibli endüstriyel süpürge Error-Codes error codes
Codes
- A2Error codeNot an actual alarm-Medium
- U-00Error codeCommunication error- In order to properly communicate the inverter needs to have the required power to the inverter. It will also digitally communicate with the inverterHigh
- U-09Error codeInverter parameters are not recognized- Inverter has to be able to talk with the microprocessor. Loading parameters allows this communicationMedium
- U-39Error codeInverter fault- Fault in inverters internal controlMedium
- U-41Error codeInverter to motor fault - A fault in one of the three inverter/ motor output phasesMedium
- U-50Error codeShort detected in the motor windings- A short in the motor or motor winding. This could be a short phase to phase, phase to housing, or phase to klixonMedium
- U-56Error codeHigh
- UA11Error codeOpen phase error- Loss of motor phase during operation Motor not connected- Motor disconnected during operationMedium
- UA13Error codeADC hardware error- Inverter has failed Electronic circuit error- Internal component of the inverter is damaged Inrush current failure- Inverter has failedMedium
- UA14Error codeOver current diversion- Inverter is detecting an over current situationMedium
- UA16Error codeInverter overcurrent error-Medium
- UA17Error codeInverter overload error- Excessive motor consumption Motor over temperature error Motor over temperatureMedium
- UA18Error codeUnder voltage on the DC buss Low voltage on the DC buss Error in V buss sensor- Voltage errorCritical
- UA19Error codeInverter over voltage- Excessive voltage on the inverter’s DC bussCritical
- UA20Error codeInverter general errorMedium
- UA21Error codeInverter over heating error- Inverter power circuit over heatedMedium
- UA22Error codeVoltage error- Supply voltage is out of range Motor system error- Inverter’s microprocessor is not functioning properlyHigh
- UA23Error codeSpeed limitation error- Compatibility error between the microprocessor and the inverterMedium
- UA25Error codeInverter communication error-High
- UA27Error codeStartup fail error- Machine did not initialize when power was turned onHigh
- UA29Error codeOvercurrent diversion error- Internal permanent magnet issue on the motor I2T overcurrent error Inverter errorMedium
- UA39Error codeInverter fan error- Fault with the inverter’s fanHigh
- V-10Error codeInput inverter voltage out of range- Incorrect incoming voltage to inverterHigh
- V-11Error codeUnbalanced amperage draw- The inverter detects an unbalanced amperage draw in between the motor and inverterMedium
- V-15Error codeLow inverter voltage- The inverter is detecting a lower than normal voltage readingHigh