Immergas Victrix 26 2 I error codes
Codes
- d2Error codeDisplays the primary exchanger output instant heating fol w temperatureHigh
- d3Error codeDisplays the instant output temperature from the DHW exchangerHigh
- d6Error codeDisplays the external temperature (if external probe present) If the temperature is below zero, the value is displayed fal shingHigh
- d7Error codeDisplay the temperature of the inlet DHW (with DHW inlet probe present)High
- d9Error codeDisplays the list of the last fvi e anomalies.High
- M1Error codeBoiler pumpHigh
- M30Error code3-way valve (motorised)High
- P0Error codeEstablishes the switch-of fmethod in DHW mode. 1 Correlated: the boiler switches off on the basis of the temperature set.High
- P2Error codeThe pump can function in two ways. 0 intermittent: In winter "mode" the pump is managed by the room thermostat or by the remote control 1 continuous: In "winter" mode the pump is always powered and so functions continuouslyHigh
- P3Error codeThe boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 = Main zone control 2 =General alarm 3 = CH phase active 4 = External gas valve power supply 5 = (Do not use on this boiler model)Critical
- P4Error codeThe boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 =General alarm 2 = CH phase active 3 = External gas valve power supply 4 = Secondary zone control (from TA on relay board contact 5 = Heat pumpCritical
- P5Error codeThe boiler is set-up for functioning with the relay board (optional), which can be configured 0 = Off 1 = Chiller remote activation 2 =General alarm 3 = CH phase active 4 = External gas valve power supply 5 = heat pump 6 = activation of storage tank pumpCritical
- R5Error codeDomestic hot water temperature trimmerHigh
- R6Error codeCentral heating temperature trimmerHigh
- S0Error codeThe boiler also has electronic modulation that adapts the boiler potentiality to the efef ctive heating demand of the house. Teh refore the boiler works normally in a variable gas pressure fei ld between minimum and maximum power depending on the system heat load, setting fan speed (in rpm, hundreds of revs are represented on the display). N.B.:the boiler is produced and calibrated in the central heating phase at nominal output. Approximately 10 minutes are needed to reach the nominal heat output, which can be changed using the parameter (S3). N.B.: selection of parameters in the presence of requests, allows boiler functioning with current equal to the respective valueCritical
- S5Error codeSystem pressure switchHigh
- S6Error codeDefni es the maximum fol w temperatureHigh
- T2Error codeLow voltage transformerCritical
- t4Error codeEstablishes what the indicator displays 14 (Fig. 2-1).High